session.lightSensor reads the ambient light sensor on the glasses. It needs
custom firmware: the G2 (Glassly CFW or upstream g2flash) or the MemoMind One
(Glassly CFW). Stock firmware and other glasses reject its control requests.
src/background/index.ts
stop() or the miniapp
closes.
Reading light
query() asks for the driver’s cached value without opening the sensor. The
answer arrives through onUpdate() with reason: "query" and may be stale.
start(options?) polls the sensor and, on the G2, pauses the stock automatic
brightness adjustments while polling. Calling it again re-applies new options.
stop() restores stock behavior without changing the brightness setting.
Each
LightSensorData has:
MemoMind One
The MemoMind One firmware buffers its light readings and the phone polls that buffer, never faster than every 500 ms, applyingminDelta and heartbeatMs
itself; a reading can trail the sensor by up to one poll. On Glassly CFW
revision 14 the glasses sample the sensor at intervalMs themselves; on
revisions 10 to 13 they only buffer the stock reader’s roughly once-a-second
samples, which stop while auto-brightness is off. Polling does not depend on the
miniapp display on these glasses.
Ownership
One miniapp controls the sensor at a time. Others can observe readings but cannot reconfigure or stop it; theirstart() and stop() reject with
INVALID_ARGUMENT. Closing the owning miniapp releases the sensor. A
session.navigation trip on the glasses
temporarily takes the sensor back and polling resumes afterward.
Polling is bound to the custom firmware’s display lease: opening a stock screen
on the glasses or letting the miniapp display go idle stops polling. Call
start() again when your content returns.
Successful delivery of a command is not proof of a fresh sample.
start()
rejects with INTERNAL when the firmware refuses or never acknowledges it, for